  1. PART 1 - GENERAL

    1. 1.1  SUMMARY
      1. WORK INCLUDES
        1. SlateSpacer
        2. Provide appropriate SlateSpacers for the roof system.
      2. RELATED SECTIONS
        1. Division 7: Thermal and Moisture Protection.
        2. Section 07310: Natural Slate Shingles.
        3. Section 07600: Flashing and Sheet Metal.
    2. 1.2  SYSTEM
      1. COMPONENTS:
        1. Standard SlateSpacer
        2. Edge SlateSpacer
      2. DESIGN REQUIREMENTS:
        1. Joint space: horizontally adjacent slates should be a minimum of 5/32" (3 mm) apart
    3. 1.3  SUBMITTAL - Submit manufacturer's Installation Guide.
    4. 1.4  QUALITY ASSURANCE - Installer to be experienced in the installation of roofing slate, having applied at least four complete slate roofs for not less than 4 years in the area of the project.
    5. 1.5  DELIVERY / STORAGE / HANDLING - Inspect material upon delivery and order replacements for any missing or defective items.
  2. PART 2 - PRODUCTS

    1. 2.1  MANUFACTURER
      1. Ardelis LLC, 1220 N. Market St., Suite 806, Wilmington, Delaware, 19801, USA; www.slatespacer.com; email: slatespacer@slatespacer.com; telephone +1 302 652 0834, fax +1 302 652 6656
    2. 2.2  MATERIALS
      1. Standard and Edge SlateSpacer
      2. Stainless steel, 302 or 304 (unless otherwise specified)
    3. 2.3  FINISH - All spacers provided mill finish.
  3. PART 3 - EXECUTION

    1. 3.1  SLATE INSTALLATION
      1. Joint space: Leave a minimum of 5/32" (3 mm) between horizontally adjacent slates.
    2. 3.2  SLATESPACER INSTALLATION
      1. Comply with manufacturer's Installation Guidelines.

top